15 pages. Assigns work to containment levels by risk group, defines biological safety cabinet practice including what the cabinet does not protect against, and lists ten aerosol generating procedures with the control required for each. Covers four spill scenarios step by step, a ten point list of prohibited practices, immediate containment of a suspected high consequence organism, and post exposure management with immunization and surveillance requirements